Experiment 1: Errors, Uncertainties, and Measurements
Autor: Tim • October 29, 2017 • 2,737 Words (11 Pages) • 894 Views
...
Figure 1: Experimental Set-up for Foot Rule
Figure 2: Experimental Set-up for Vernier Caliper[pic 16]
Figure 3: Experimental Set-up for Micrometer Caliper
4. Results and Discussion
Table 1- Foot Rule
Trial
Diameter (cm)
Deviation from mean diameter
1
1.4
.01
2
1.4
.01
3
1.3
.09
4
1.4
.01
5
1.4
.01
6
1.4
.01
7
1.4
.01
8
1.4
.01
9
1.4
.01
10
1.4
.01
Mean Diameter
1.39
Average Deviation (a.d)
0.018
Average Deviation of the Mean (A.D)
0.0006
% Error Diameter
0.4
Volume (cm3)
1.41
Mass (g)
16.26
Experimental Value of Density (g/cm3)
11.53
Accepted Value of Density (g/cm3)
7.874
% Error of Density
46.43
[pic 17]
Table 2- Vernier Caliper
Trial
Diameter (cm)
Deviation from mean diameter
1
1.525
.001
2
1.525
.001
3
1.520
.004
4
1.520
.004
5
1.520
.004
6
1.530
.006
7
1.525
.001
8
1.525
.001
9
1.525
.001
10
1.520
.004
Mean Diameter
1.524
Average Deviation (a.d)
0.002
Average Deviation of the Mean (A.D)
0.006
% Error Diameter
0.04
Volume (cm3)
1.85
Mass (g)
16.26
Experimental Value of Density (g/cm3)
8.79
Accepted Value of Density (g/cm3)
7.874
% Error for Density
11.93
Table 3- Micrometer Caliper
Trial
Diameter (cm)
Deviation from mean diameter
1
1.5800
.003
2
1.5781
.001
3
1.5746
.002
4
1.5764
.003
5
1.5749
.002
6
1.5760
.007
...